  Now, in order to improve the processing speed and processing quality, the furniture manufacturing industry has purchased a large number of CNC equipment. Common equipment includes cutting machines, edge banding machines, side hole machines and other equipment. Some problems affect the normal use. Next, Blue Elephant CNC will introduce in detail what is the operation failure of the woodworking edge banding machine ? Next, let's take a look together!
1. Electrical failure. Including host shutdown, slow temperature rise, program disorder, etc. If it is not eliminated in time, the motor and heating tube will burn out, and even damage the entire mechanical system. During maintenance, mainly check the electrical control box, motor, heating tube, delay device, etc. This kind of overhaul is generally maintained by professionals or manufacturers.
2. The gas circuit is faulty. Including air valve failure, air leakage, low air pressure, cutter and feeding failure, etc. Mainly check the integrity of various pneumatic components, and replace parts under the guidance of the manufacturer's technicians.
edge banding machine
3. Mechanical failure. There are mainly transmission failures, uneven gluing, feeding failures, tool failures, etc. The main thing is to check the integrity and firmness of all mechanical parts, and whether the transmission parts are misaligned.
4. Bonding failure. Such as sticking, deviation, entrainment, etc. This is a comprehensive failure, related to the rubber shaft, edge banding, solution, substrate, and operation. Such failures may occur at the same time or separately, and the specific maintenance depends on the situation.
The operation failure of the woodworking edge banding machine has been summarized in detail for you in the above content. Here we remind you that when using it, you must do a good job of checking the equipment to avoid equipment failure during use. If there is a problem, you must stop the operation, otherwise it will cause more serious damage to the equipment and affect normal use.